Skip to main content

EcoSystem 50 Standard

Technical information

Performance

Insulation

Thermal insulation (Best) - Uf
2.6 W/m²K
Thermal insulation - Uw
1.6 W/m²K
Uw Dependencies
Frame-vent: Ug 1.0W/m²K, psi: 0.032W/mK @1.23x1.48m (92mm sight line), 24mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class 9A (600Pa)
Wind load resistance
Class C4 (1600Pa)
Acoustics - Rw(C;Ctr)
39(-1;-3) dB dB
Durability
Class 2 (10000 cycles)

Safety & Security

Burglar resistance
RC2
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Max. height of vent
2200 mm
Min. width of vent
450 mm
Max. width of vent
1600 mm
Max. weight of vent
120 kg

Sightlines

Min. frame width (inward opening)
48 mm
Min. vent width (inward opening)
30 mm
Min. frame-vent width (inward opening)
86 mm
Min. frame width (outward opening)
21 mm
Min. vent width (outward opening)
87 mm
Min. frame-vent width (outward opening)
108 mm