MasterLine 10
Technical informationPerformance
Insulation
- Thermal insulation (Best) - Uf
- 0.96 W/m²K
- Uw Dependencies
- Single inward opening door: Ug 0.6W/m²K, warm edge spacer, @1.23x2.18m, 48mm glass
- Thermal insulation - Ud
- 0.81 W/m²K
Comfort
- Air tightness
- Class 4 (600Pa)
- Water tightness
- Class 9A (600Pa)
- Wind load resistance
- Class C3 (1200Pa)
- Acoustics - Rw(C;Ctr)
- 40 (-1;-5) dB
- Durability
- Class 8 (1000000 cycles)
Safety & Security
- Burglar resistance
- RC2
Properties
Max. dimensions & weight
- Max. height of vent
- 3000 mm
- Min. width of vent
- 500 mm
- Max. width of vent
- 1400 mm
- Max. weight of vent
- 250 kg
- Max. weight of glass
- 1200 kg
Sightlines
- Min. frame width (inward opening)
- 83.5 mm
- Min. vent width (inward opening)
- 71.5 mm
- Min. frame-vent width (inward opening)
- 162 mm
- Min. frame width (outward opening)
- 27 mm
- Min. vent width (outward opening)
- 110.5 mm
- Min. frame-vent width (outward opening)
- 162 mm
- Min. width transom profile
- 87 mm
- Min. height threshold
- 0 mm
- Depth frame
- 97 mm
- Depth Vent
- 97 mm
- Depth frame-vent
- 97 mm
- Max. depth transom
- 97 mm
Glazing
- Rebate height
- 27 mm
- Glazing method
- Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
- Min. glass thickness - frame/element
- 20 mm
- Max. glass thickness - frame/element
- 78 mm
- Min. glass thickness - vent
- 20 mm
- Max. glass thickness - vent
- 78 mm