MasterLine 8 Functional
Technical informationPerformance
Insulation
- Thermal insulation (Best) - Uf
- 1.1 W/m²K
- Uw Dependencies
- Single inward opening door: Ug 0.6W/m²K, psi: 0.032W/mK @1.23x2.18m, 134mm sight-line & 36mm glass
- Thermal insulation - Ud
- 0.89 W/m²K
Comfort
- Air tightness
- Class 4 (600Pa)
- Water tightness
- Class 8A (450Pa)
- Wind load resistance
- Class C2 (800Pa)
- Acoustics - Rw(C;Ctr)
- 43(-1;-4) dB
- Durability
- Class 8 (1000000 cycles)
Safety & Security
- Burglar resistance
- RC2 - RC3 - PAS 24
- Impact resistance
- I5 - E5
Properties
Max. dimensions & weight
- Min. height of vent
- 500 mm
- Max. height of vent
- 3000 mm
- Min. width of vent
- 500 mm
- Max. width of vent
- 1400 mm
- Max. weight of vent
- 250 kg
- Max. weight of glass
- 1200 kg
Sightlines
- Min. frame width (inward opening)
- 68.5 mm
- Min. vent width (inward opening)
- 78.5 mm
- Min. frame-vent width (inward opening)
- 147 mm
- Min. frame width (outward opening)
- 42.5 mm
- Min. vent width (outward opening)
- 104.5 mm
- Min. frame-vent width (outward opening)
- 147 mm
- Min. width transom profile
- 80 mm
- Min. height threshold
- 0 mm
- Depth frame
- 77 mm
- Depth Vent
- 77 mm
- Depth frame-vent
- 77 mm
Glazing
- Rebate height
- 27 mm
- Glazing method
- Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
- Min. glass thickness - frame/element
- 6 mm
- Max. glass thickness - frame/element
- 57 mm
- Min. glass thickness - vent
- 13 mm
- Max. glass thickness - vent
- 67 mm