Skip to main content

MasterLine 8 Renaissance

Technical information

Performance

Insulation

Thermal insulation (Best) - Uf
1.1 W/m²K
Uw Dependencies
Single inward opening door: Ug 0.6W/m²K, psi: 0.032W/mK @1.23x2.18m, 134mm sight-line & 36mm glass
Thermal insulation - Ud
0.89 W/m²K

Comfort

Air tightness
Class 3 (600Pa)
Water tightness
Class E1200 (1200Pa)
Durability
Class 5 (100000 cycles)

Safety & Security

Impact resistance
I5 - E5
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent
500 mm
Max. height of vent
3000 mm
Min. width of vent
500 mm
Max. width of vent
1400 mm
Max. weight of vent
150 kg
Max. weight of glass
1200 kg

Sightlines

Min. frame width (inward opening)
53 mm
Min. vent width (inward opening)
52 mm
Min. frame-vent width (inward opening)
105 mm
Min. frame width (outward opening)
20 mm
Min. vent width (outward opening)
96 mm
Min. frame-vent width (outward opening)
116 mm
Min. width transom profile
80 mm
Min. height threshold
0 mm
Depth frame
87 mm
Depth Vent
87 mm
Depth frame-vent
97 mm

Glazing

Rebate height
27 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
Min. glass thickness - frame/element
4 mm
Max. glass thickness - frame/element
62 mm
Min. glass thickness - vent
13 mm
Max. glass thickness - vent
72 mm