Skip to main content

MasterLine 8 Standard

Technical information

Performance

Insulation

Thermal insulation (Best) - Uf
2 W/m²K
Uw Dependencies
Single inward opening door: Ug 0.6W/m²K, psi: 0.032W/mK @1.23x2.18m, 153mm sight line & 36mm glass
Thermal insulation - Ud
1.2 W/m²K

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class 8A (450Pa)
Wind load resistance
Class C2 (800Pa)
Acoustics - Rw(C;Ctr)
43(-1;-4) dB
Durability
Class 8 (1000000 cycles)

Safety & Security

Burglar resistance
RC2 - RC3 - PAS 24
Impact resistance
I5 - E5
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent
500 mm
Max. height of vent
3000 mm
Min. width of vent
500 mm
Max. width of vent
1400 mm
Max. weight of vent
250 kg
Max. weight of glass
1200 kg

Sightlines

Min. frame width (inward opening)
68.5 mm
Min. vent width (inward opening)
78.5 mm
Min. frame-vent width (inward opening)
153 mm
Min. frame width (outward opening)
42.5 mm
Min. vent width (outward opening)
104.5 mm
Min. frame-vent width (outward opening)
153 mm
Min. width transom profile
80 mm
Min. height threshold
0 mm
Depth frame
77 mm
Depth Vent
77 mm
Depth frame-vent
77 mm

Glazing

Rebate height
27 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
Min. glass thickness - frame/element
6 mm
Max. glass thickness - frame/element
57 mm
Min. glass thickness - vent
13 mm
Max. glass thickness - vent
67 mm