Skip to main content

ConceptWall 50 Structural Clamped

Technical information

Performance

Insulation

Thermal insulation - Utj
5.7 W/m²K

Comfort

Air tightness
AE 1200 (1200Pa)
Water tightness
RE1200 (1200 Pa)
Wind load resistance
E2400 (2400Pa)
Acoustics - Rw(C;Ctr)
47(-2;-6) dB

Safety & Security

Impact resistance
I5 - E5
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Min. width of vent
450 mm
Max. weight of vent
180 kg
Min. intertia mullion - Ix
13.5 cm4
Max. intertia transom - Ix
534.7 cm4
Min. intertia transom - Iy (glass load)
7.9 cm4
Max. intertia transom - Iy (glass load)
59 cm4

Sightlines

Min. width transom profile
50 mm
Min. visible width (interior view)
50 mm
Min. visible width (exterior view)
50 mm
Min. depth mullion
41.5 mm
Max. depth mullion
300 mm
Min. depth transom
5 mm

Glazing

Rebate height
20 mm
Glazing method
Dry glazing - External glazing - Structural clamped glazing
Min. glass thickness - frame/element
27 mm
Max. glass thickness - frame/element
63 mm