ConceptWall 60 Hidden Vent
Technical informationPerformance
Insulation
- Thermal insulation (Best) - Uf
- 0.95 W/m²K
Comfort
- Air tightness
- AE 1200 (1200Pa)
- Water tightness
- RE1200 (1200 Pa)
- Acoustics - Rw(C;Ctr)
- 44(-1;-3) dB
Safety & Security
- Impact resistance
- I4
- Operating Forces Class
- Class 1
Properties
Max. dimensions & weight
- Min. height of vent
- 685 mm
- Max. height of vent
- 2800 mm
- Min. width of vent
- 636 mm
- Max. width of vent
- 1350 mm
- Max. weight of vent
- 150 kg
- Min. intertia mullion - Ix
- 77.65 cm4
- Max. intertia mullion - Ix
- 77.65 cm4
- Min. intertia transom - Ix
- 81.25 cm4
- Max. intertia transom - Ix
- 81.25 cm4
- Min. intertia transom - Iy (glass load)
- 95.68 cm4
Sightlines
- Min. width transom profile
- 60 mm
- Min. visible width (interior view)
- 65 mm
- Min. visible width (exterior view)
- 60 mm
- Min. depth mullion
- 104.5 mm
- Max. depth mullion
- 104.5 mm
- Min. depth transom
- 104.5 mm
- Max. depth transom
- 104.5 mm
Glazing
- Rebate height
- 25 mm
- Glazing method
- Pressure plate glazing
- Min. glass thickness - frame/element
- 6 mm
- Max. glass thickness - frame/element
- 64 mm
- Min. glass thickness - vent
- 24 mm
- Max. glass thickness - vent
- 57 mm