Performance

Insulation

Thermal insulation (Best) - Uf
2.3 W/m²K
Thermal insulation - Uw
1.4 W/m²K
Uw Dependencies
Frame-vent HI+: Ug 1.0W/m²K, warm edge spacer,@1.23x1.48m (86mm sight line), 24mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class 9A (600Pa)
Wind load resistance
Class C3 (1200Pa)
Durability
Class 2 (10000 cycles)
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent
700 mm
Max. height of vent
2200 mm
Min. width of vent
500 mm
Max. width of vent
1600 mm

Sightlines

Min. frame-vent width (inward opening)
92 mm
Min. vent-vent width (inward opening)
134 mm
Min. frame width (outward opening)
21 mm
Min. vent width (outward opening)
73 mm
Min. width transom profile
70 mm
Depth frame
50 mm
Depth Vent
59 mm
Depth frame-vent
59 mm

Glazing

Rebate height
22 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead
Min. glass thickness - frame/element
12 mm
Max. glass thickness - frame/element
32 mm
Min. glass thickness - vent
4 mm
Max. glass thickness - vent
32 mm