EcoSystem 50
Technical informationPerformance
Insulation
- Thermal insulation (Best) - Uf
- 2.6 W/m²K
- Thermal insulation - Uw
- 1.5 W/m²K
- Uw Dependencies
- Frame-vent: Ug 1.0W/m²K, warm edge spacer, @1.23x1.48m (92mm sight line), 24mm glass
Comfort
- Air tightness
- Class 4 (600Pa)
- Water tightness
- Class 9A (600Pa)
- Wind load resistance
- Class C4 (1600Pa)
- Acoustics - Rw(C;Ctr)
- 38(-1;-2) dB
- Durability
- Class 2 (10000 cycles)
Safety & Security
- Burglar resistance
- RC2
Properties
Max. dimensions & weight
- Min. height of vent
- 700 mm
- Max. height of vent
- 2200 mm
- Min. width of vent
- 500 mm
- Max. width of vent
- 1600 mm
- Max. weight of vent
- 120 kg
Sightlines
- Min. frame width (inward opening)
- 48 mm
- Min. vent width (inward opening)
- 30 mm
- Min. frame-vent width (inward opening)
- 86 mm
- Min. frame width (outward opening)
- 21 mm
- Min. vent width (outward opening)
- 73 mm
- Min. frame-vent width (outward opening)
- 99.5 mm
- Min. width transom profile
- 70 mm
- Depth frame
- 50 mm
- Depth Vent
- 59 mm
- Depth frame-vent
- 50 mm
Glazing
- Rebate height
- 22 mm
- Glazing method
- Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead
- Min. glass thickness - frame/element
- 12 mm
- Max. glass thickness - frame/element
- 32 mm
- Min. glass thickness - vent
- 4 mm
- Max. glass thickness - vent
- 32 mm