MasterLine 10 Renaissance
Technical informationPerformance
Insulation
- Thermal insulation (Best) - Uf
- 0.99 W/m²K
- Thermal insulation - Uw
- 0.78 W/m²K
- Uw Dependencies
- Frame-vent: Ug 0.6W/m²K, psi: 0.032W/mK @1.23x1.48m (104mm sight line), 48mm glass
Comfort
- Air tightness
- Class 4 (600Pa)
- Water tightness
- Class E900 (900Pa)
- Wind load resistance
- Class C4 (1600Pa)
- Acoustics - Rw(C;Ctr)
- TuTi: 46(-1;-4) dB DC: 44(-2;-4) dB
- Durability
- Class 3 (20000 cycles)
Safety & Security
- Burglar resistance
- RC2 - RC3
- Operating Forces Class
- Class 1
Properties
Max. dimensions & weight
- Min. height of vent
- 600 mm
- Max. height of vent
- 2800 mm
- Min. width of vent
- 550 mm
- Max. width of vent
- 1700 mm
- Max. weight of vent
- 200 kg
- Max. weight of glass
- 1200 kg
Sightlines
- Min. frame width (inward opening)
- 60 mm
- Min. vent width (inward opening)
- 37 mm
- Min. frame-vent width (inward opening)
- 104 mm
- Min. vent-vent width (inward opening)
- 191 mm
- Min. frame width (outward opening)
- 27 mm
- Min. vent width (outward opening)
- 118 mm
- Min. frame-vent width (outward opening)
- 145 mm
- Min. width transom profile
- 87 mm
- Depth frame
- 107 mm
- Depth Vent
- 107 mm
- Depth frame-vent
- 117 mm
Glazing
- Rebate height
- 27 mm
- Glazing method
- Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead - Structural Glued Glazing
- Min. glass thickness - frame/element
- 20 mm
- Max. glass thickness - frame/element
- 78 mm
- Min. glass thickness - vent
- 20 mm
- Max. glass thickness - vent
- 78 mm