Skip to main content

MasterLine 10

Technical information

Performance

Insulation

Thermal insulation (Best) - Uf
0.99 W/m²K
Thermal insulation - Uw
0.8 W/m²K
Uw Dependencies
Frame-vent: Ug 0.6W/m²K, warm edge spacer, @1.23x1.48m (104mm sight line), 48mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E900 (900Pa)
Wind load resistance
Class C4 (1600Pa)
Acoustics - Rw(C;Ctr)
TuTi: 46(-1;-4) dB DC: 44(-2;-4) dB
Durability
Class 3 (20000 cycles)

Safety & Security

Burglar resistance
RC2 - RC3
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Max. height of vent
2800 mm
Min. width of vent
550 mm
Max. width of vent
1200 mm
Max. weight of vent
200 kg
Max. weight of glass
1200 kg

Sightlines

Min. frame width (inward opening)
60 mm
Min. vent width (inward opening)
37 mm
Min. frame-vent width (inward opening)
104 mm
Min. frame width (outward opening)
27 mm
Min. vent width (outward opening)
113 mm
Min. frame-vent width (outward opening)
140 mm
Min. width transom profile
87 mm
Depth frame
97 mm
Depth Vent
107 mm
Depth frame-vent
107 mm

Glazing

Rebate height
27 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
Min. glass thickness - frame/element
20 mm
Max. glass thickness - frame/element
78 mm
Min. glass thickness - vent
30 mm
Max. glass thickness - vent
88 mm